Matthew Guthaus
03/11/2022, 3:48 PMNetlists do not match.
Networks match locally but not globally.
Probably connections are swapped.
Check the end of logfile lvs.out for implicated nodes.
NET mismatches: Class fragments follow (with fanout counts):
Circuit 1: cell_1rw |Circuit 2: cell_1rw
---------------------------------------------------------------------------------------
Net: QB |Net: QB
sky130_fd_pr__nfet_01v8/(1|3) = 2 | sky130_fd_pr__nfet_01v8/(1|3) = 2
sky130_fd_pr__nfet_01v8/2 = 1 | sky130_fd_pr__nfet_01v8/2 = 1
sky130_fd_pr__pfet_01v8/2 = 1 | sky130_fd_pr__pfet_01v8/2 = 1
sky130_fd_pr__pfet_01v8/(1|3) = 1 | sky130_fd_pr__pfet_01v8/(1|3) = 1
|
Net: Q |Net: Q
sky130_fd_pr__nfet_01v8/(1|3) = 2 | sky130_fd_pr__pfet_01v8/2 = 1
sky130_fd_pr__pfet_01v8/(1|3) = 1 | sky130_fd_pr__nfet_01v8/(1|3) = 2
sky130_fd_pr__pfet_01v8/2 = 1 | sky130_fd_pr__pfet_01v8/(1|3) = 1
sky130_fd_pr__nfet_01v8/2 = 1 | sky130_fd_pr__nfet_01v8/2 = 1
---------------------------------------------------------------------------------------