@jeffdi@Tim Edwards My other dies are worse than the first. I'm having trouble getting the first chain to completely program. It usually stops around bit 8-11
t
Tim Edwards
02/16/2023, 12:51 AM
Have you tried calibrating at a vccd1 voltage of 1.43V?
m
Matthew Guthaus
02/16/2023, 4:22 PM
Yes
1.42 actually, I'll try 1.43
1.45 seemed to do better than lower
t
Tim Edwards
02/16/2023, 7:10 PM
Your "best part" should be able to be configured properly for test, but the existing software for the configuration builder needs to be modified, as I mentioned in the other thread.
m
Matthew Guthaus
02/16/2023, 7:24 PM
@Tim Edwards We were using the best part yesterday during our call.
There's a chance that something else might be affecting it. I have a wire on GPIO0 that could be loading it extra and causing pulses to be missed.