<#313 gf180 IO liberties have duplicate definition...
# open_pdks
g
#313 gf180 IO liberties have duplicate definitions for cell `gf180mcu_fd_io__fill10` New issue created by passant5 This produces an error in reading the liberties for timing analysis. The duplicate definitions could be found in all liberties starting at lines
2906
and
2929
For example:
Copy code
gf180mcuC/libs.ref/gf180mcu_fd_io/liberty/gf180mcu_fd_io__ff_n40C_5v50.lib
2906:	cell ("gf180mcu_fd_io__fill10") {
2929:	cell ("gf180mcu_fd_io__fill10") {
RTimothyEdwards/open_pdks