```Violation Message "MiM cap bottom plate spacing...
# shuttle-precheck
a
Copy code
Violation Message "MiM cap bottom plate spacing < 1.2um (capm.2b) "found 360 Times. (Inside the Example POR Cell that comes with the Analog Caravel)
Violation Message "P-diff distance to N-tap must be < 15.0um (LU.3) "found 84 Times. (This seems bogus to me. There is a close tap to the transitor. Not sure why it's highlighting.)
Violation Message "N-diff distance to P-tap must be < 15.0um (LU.2) "found 3 Times. (This seems bogus to me. There is a close tap to the transitor. Not sure why it's highlighting.)
 DRC Checks on GDS Failed, Reason: Total # of DRC violations is 447
p
Are you sure the wells are fully connected?
@Tim Edwards ^^ I think DRC issues are your domain, right?
a
@Philipp Gühring 100%
One sec
I'll get a pic
image.png
The tap is wrapping around the device.
It's a skinny and long device.
@Philipp Gühring The tap is part of our device generators.
p
@Amro Tork What is your repository URL?
a
I'm pushing the cleanest version that I have
one sec
@Philipp Gühring Here you go
I have flattened the entire repo.
Just to make my life easy
p
grafik.png
This design seems to be DRC clean to me, at least in magic
a
@Philipp Gühring If you run precheck, it gives the violations.
I’m relaying on the prechecker
Didn’t run it magic.
@Philipp Gühring I could upload the results file
I have to admit I don’t go to a full extent of building a full guard ring for LU protection.
But the pickup connection is there