process question. Abutting tap and diffusion are e...
# sky130
m
process question. Abutting tap and diffusion are effectively shorted due to salicide even though one is p+ and the other is n+, right?
a
isnt it just a diode?
m
My understanding is that ever since they started adding salicide on top of tap/diffusion, the anode and cathode of the underlying P/N junction would be shorted.