Hugo Dias
08/24/2022, 1:42 PMMitch Bailey
08/24/2022, 2:12 PM# NOTE: In accordance with the LVS manager GUI, the schematic is
# always circuit2, so some items like property "par1" only need to
# be specified for circuit2.
So if the layout is on the left, looks like your net3 equivalent node is shorted to gnd.
The tap right above the net3
text appears to be part of net3
. Although you may have pwell drawn, this is not used in connectivity calculations, so you may be shorting through substrate. If you need pwell that is not connected to substrate, use dnwell surrounded by nwell.Hugo Dias
08/24/2022, 4:56 PMHugo Dias
08/24/2022, 4:57 PMMitch Bailey
08/24/2022, 5:09 PMHugo Dias
08/24/2022, 5:15 PMMitch Bailey
08/24/2022, 5:37 PM