Of course the cap is not "polarized" but the rounded edge indicates the capacitor bottom, which is useful to know if you are trying to carefully control parasitics.
For MiM caps, the general rule is to always contact both cap plates from above so as to avoid turning the capacitor into a large antenna during manufacturing, which can damage the capacitor. SkyWater does not have any such rule, so I mention it as an advisory because other foundries do have such a rule and enforce it through DRC.