Hi, I have LVS error related to "no matching net"...
# lvs
b
Hi, I have LVS error related to "no matching net" I checked logs/signoff/28-user_project_wrapper.lef.lvs.log and see some mismatch for vssd1 & vccd1 nets, here is the summary (summary is the first image) so I have connection issues in cby_* modules, which are 120x60 um sizes I checked the layout and some cby modules seems not to be connected to horizontal MET5 VCC and VSS straps: So, does the layout cause problem of "no matching net" ? If yes, then I think I need to change macro positions to overlap MET5 straps? Thanks
m
@Burak Aykenar Exactly. You’ll probably need to adjust the vertical positioning of your macros so that they intersect both vss and vcc.
b
Thanks @Mitch Bailey I updated the positions of the macros and LVS passed!
👍 1