How to check temperature variation in xschem? I am designing BGR.
s
Stefan Schippers
08/16/2023, 11:48 AM
you can do a dc sweep over temperature:
.dc temp -40 125 0.1
a
ALOK PRATAP SINGH
08/17/2023, 4:40 AM
in transient, Where I need to give. @Stefan Schippers
s
Stefan Schippers
08/27/2023, 8:07 AM
Transient simulations can only be run at a fixed temperature.
you can do multiple transient simulations each at a different temperature and append the simulation data onto the same .raw file,