wisla morais
02/02/2023, 2:18 AMforeach loop. So, using transient analysis (tran 0.41n 3u 0 4p), I used meas tran dorms RMS v(do) from=0 to=3u ; meas tran dinrms RMS v(din) from=0 to=3u and let cg = dorms/dinrms for each amplitude value. I would like to know if this simulation schematic that I created makes sense and its the best way for obtain this simulation.Stefan Schippers
02/02/2023, 7:06 PMwisla morais
02/02/2023, 8:42 PMStefan Schippers
02/02/2023, 8:43 PMStefan Schippers
02/02/2023, 10:15 PMtar.gz file creates a conv_detector directory. Start xschem inside this directory.
I think your approach is correct. This is not a small signal analysis so no .AC can be used. I have made some mesurements in xschem and the values for dinrms, dorms and cg confirm the printed values. Image shows the results for the highest amp param value.Stefan Schippers
02/02/2023, 10:19 PMdo goes quickly to zero. Anyway i am not a UHF expert so I might just be ignorant :-)wisla morais
02/03/2023, 2:39 AMLinen is a search-engine friendly community platform. We offer integrations with existing Slack/Discord communities and make those conversations Google-searchable.