As <@U01819B63HP> says, temperature can also be se...
# xyce
e
As @User says, temperature can also be set using a .STEP command. This works fine, but it has one possible drawback. .STEP currently doesn’t work with our “restart” capability. If running a long transient Xyce can output restart files at specified times. That way if you only want to re-run a later stage of a calculation, you can use restart. But, like I said, restart only works if you are NOT using a .STEP loop. But if you don’t care about restart, then using .STEP works just as well.
👍 1
💪 1
m
Oh neat, you can stop and view intermediate results?
e
Yes. If you have set up the original simulation which produced the restart files to do outputs, those output files will be produced.