does?
For example what does asserting it to 1 like this
reg_la_sample = 1
will do?
m
Matthew Guthaus
02/25/2022, 4:48 AM
I've found that the best documentation is, unfortunately, the Verilog code itself.
t
Tim Edwards
02/27/2022, 3:45 PM
@User: The intent of the
sample
register was to simultaneously capture all of the logic analyzer inputs (on the same clock edge). However, no testbench was written for this, and it looks like it has no useful function because there is no way to read back the value to the management SoC. It needs two fixes, I think, one of which is a self-reset of the
sample
bit (otherwise it is effectively setting
sample
to zero that freezes the captured value, which is a kind of awkward implementation), and the other which is to add a second control bit which will switch the read-back value on the logic analyzer registers between
la_data_in
and
la_data
. I am going to file an issue on github about this.
h
Hadir Khan
02/27/2022, 4:55 PM
Yes, using it was causing freezing up in the simulation resulting in timeout.