Hello everyone, I couldn't find the error here. If anyone knows what it is, I would appreciate it.
P-diff distance to N-tap must be < 15.0um (LU.3)
m
Matt Liberty
10/11/2022, 3:25 AM
Do you have any well taps? From the message it sounds like you don't or they are too far away
a
Arman Avetisyan
10/11/2022, 8:01 AM
the standard cells get the same error.
This is because taps are placed outside the cell
n
Nelson Rodriguez
10/14/2022, 5:57 PM
@Matt Liberty@Arman Avetisyan I have a doubt with that, what Magic called N-tap is the same layer
nsd
(n-substrate diffusion)? I think my error was to have painted
ndiff
(n-diffussion) rather than a
nsd
, I changed it and the error disappeared. Thanks to both.
m
Matt Liberty
10/14/2022, 6:02 PM
Magic questions are best directed to @Tim Edwards
t
Tim Edwards
10/14/2022, 6:09 PM
@Nelson Rodriguez: FYI, the underlying error is that tap distances are measured, per SkyWater documentation, as the distance from a tap contact center to the nearest diffusion edge. By that definition, if you do not have a contact inside the tap layer, the distance can't be measured, and the layout fails the DRC check.