<#250 Missing Cont in IO cells> Issue created by <...
# ihp-sg13g2
g
#250 Missing Cont in IO cells Issue created by dnltz I have a design with IO ring and DRCs report
LU.d
and
LU.d1
violations. Both rules are defined as following: image As you can see in the next image, all violations are located in the IO cells itself. It looks like there is quite some
Cont
missing. (Image is showing the
LU.d
violations). image We taped-out these cells in May and used Cadence for Metal fill. We also had no
LU.d
violations in that tape-out. So, seems like Cadence is smart enough to fill the missing
Cont
filler. However, I would propose to add the missing
Cont
to the IO cells directly. It's probably easier to just add it once instead of filling it in each design. --- The following image is showing the
LU.d1
violations: image IHP-GmbH/IHP-Open-PDK